美國CIRS CT PMMA 007 DOSE Phantom CT模體
概述:深圳灣邊貿(mào)易美國CIRS CT PMMA 007 DOSE Phantom CT模體價格優(yōu)惠
賬戶:
刷新時間:
2024-07-05 09:13:23 點擊84983次
分類:
標(biāo)簽:
服務(wù)區(qū)域:
全國
價格:
- 8888 元
聯(lián)系電話:
13714972229
深圳灣邊貿(mào)易美國CIRS CT PMMA 007 DOSE Phantom CT模體價格優(yōu)惠 CIRS CT模體價格優(yōu)惠 MODEL 007 007A價格優(yōu)惠。
廠家:美國Computerized Imaging Reference Systems, Incorporated (美國CIRS)
 
For all computed tomography systems, the Food and Drug Administration recommends measuring the CT Dose Index (CTDI). Each section of the CIRS CT Dose Phantoms can provide separate dose information.  The user can also measure maximum, minimum and mid-range values of the nominal tomographic section thickness when performing dose profile measurements.
Each phantom consists of a set of nesting 15 cm thick solid PMMA disks measuring 16 cm (head) and 32 cm (body) in diameter.  The adult head disk is also suitable for pediatric body measurements. The Model 007A includes a third nesting disk measuring 10 cm in diameter for pediatric head measurements. Handles on the body and head are provided for ease in handling and maneuverability.
Through holes measuring 1.31 cm in diameter will accommodate standard CT probes. Acrylic rods are provided to plug the holes when not in use. The acrylic rods are machined to receive 1 mm diameter TLD rods.
The Model 007 & 007A are manufactured to comply with the FDA’s performance standard, 21 CFR 1020.33 that details the measurement requirements.
Features:
Abdominal, Adult Head, Pediatric Head configurations
PMMA disks and plugs with density of 1.10 g/cc
1.31 cm diameter holes sized for standard CT Dose probes
Nesting PMMA disks minimize storage space
Compatiblewith all CT scanners
An optional Support Bracket, Model 007-01, can be used to suspend the CT Dose Phantoms above the imaging couch and align it along the axis of X-ray tube rotation.  This enables the phantom to be used to assess CT dose in helical mode or any mode that requires the extended travel of the imaging couch or a wide beam.  This set-up might be used to address the dosimetry approach described in TG111.  An additional application of the support bracket is to provide a body to simulate continous scatter radiation from the patient during helical CT for dose safety measurements inside and outside the exam room. 
 
MODEL 007
 
Overall Dimensions
31.8 cm x 31.8 cm x 15 cm  (12.5 x 12.5 x 5.5)   
 
       
Weight
13 kg  (29 lb)
 
Materials
PMMA
Model 007 Includes     
(1) Abdominal Cylinder
(1) Adult Head Cylinder
(9) Acrylic Rods
(1) Foam Lined Carry Case
 
 [本信息來自于今日推薦網(wǎng)]
廠家:美國Computerized Imaging Reference Systems, Incorporated (美國CIRS)
 
For all computed tomography systems, the Food and Drug Administration recommends measuring the CT Dose Index (CTDI). Each section of the CIRS CT Dose Phantoms can provide separate dose information.  The user can also measure maximum, minimum and mid-range values of the nominal tomographic section thickness when performing dose profile measurements.
Each phantom consists of a set of nesting 15 cm thick solid PMMA disks measuring 16 cm (head) and 32 cm (body) in diameter.  The adult head disk is also suitable for pediatric body measurements. The Model 007A includes a third nesting disk measuring 10 cm in diameter for pediatric head measurements. Handles on the body and head are provided for ease in handling and maneuverability.
Through holes measuring 1.31 cm in diameter will accommodate standard CT probes. Acrylic rods are provided to plug the holes when not in use. The acrylic rods are machined to receive 1 mm diameter TLD rods.
The Model 007 & 007A are manufactured to comply with the FDA’s performance standard, 21 CFR 1020.33 that details the measurement requirements.
Features:
Abdominal, Adult Head, Pediatric Head configurations
PMMA disks and plugs with density of 1.10 g/cc
1.31 cm diameter holes sized for standard CT Dose probes
Nesting PMMA disks minimize storage space
Compatiblewith all CT scanners
An optional Support Bracket, Model 007-01, can be used to suspend the CT Dose Phantoms above the imaging couch and align it along the axis of X-ray tube rotation.  This enables the phantom to be used to assess CT dose in helical mode or any mode that requires the extended travel of the imaging couch or a wide beam.  This set-up might be used to address the dosimetry approach described in TG111.  An additional application of the support bracket is to provide a body to simulate continous scatter radiation from the patient during helical CT for dose safety measurements inside and outside the exam room. 
 
MODEL 007
 
Overall Dimensions
31.8 cm x 31.8 cm x 15 cm  (12.5 x 12.5 x 5.5)   
 
       
Weight
13 kg  (29 lb)
 
Materials
PMMA
Model 007 Includes     
(1) Abdominal Cylinder
(1) Adult Head Cylinder
(9) Acrylic Rods
(1) Foam Lined Carry Case
 
 [本信息來自于今日推薦網(wǎng)]
- coastaltrading發(fā)布的信息
- 美國CIRS 052A 乳腺模體
- 深圳灣邊貿(mào)易代理進口美國CIRS 052A 乳腺模體,價格優(yōu)惠!...
- 美國進口Magphan SMR170 模體
- 深圳灣邊貿(mào)易原裝美國進口Magphan SMR170 模體價格優(yōu)惠!...
- Liqui-Phi Phantom MRI軀干模體
- 深圳灣邊貿(mào)易代理進口Liqui-Phi Phantom MRI軀干模體價格優(yōu)惠!...
- PLATON Flostat MN系列自動流量控制器MNAS12
- 深圳市灣邊貿(mào)易有限公司優(yōu)勢供應(yīng)法國PLATON流量控制器,F(xiàn)lostat MN系列自動流量控制器MNAS12...
- Flow Network DRS-9180-N5-L342 渦輪流量傳感器
- 灣邊貿(mào)易優(yōu)勢供應(yīng)Flow Network DRS-9180-N5-L342 渦輪流量傳感器...
- HI-Q過濾紙空氣過濾 FP5211-20
- 深圳灣邊貿(mào)易美國進口HI-Q過濾紙空氣過濾 FP5211-20...